EN CN
Home / Services / Pump Encyclopedia / Pump Knowledge / Self-balance multistage pump's installation steps

Self-balance multistage pump's installation steps

05 Sep 2020Email
  • Installation of the self-balance multistage pump

 

The installation steps of the self-balance multistage pump generally include placing the pump on the foundation to find the level and the pipeline connecting the pump.

 

In addition to the general installation requirements, pay attention to the following two points when installing this type of pump:

 

a) A gap of 3 to 5 mm must be ensured between the motor coupling and the pump coupling.

 

b) The axis line of the motor and self-balance multistage pump must be a straight line in the same plane. The feeler gauge can be used to measure the uniformity of the gap between the end faces of the two couplings. In all directions of the circumference, the difference between the maximum and minimum gaps must not exceed 0.05mm. The difference between the upper and lower sides or the left and right of the center line of the two end faces does not exceed 0.05mm.

 

power plant boiler pump

 

  • Equipment required for self-balance multistage pump installation

 

Pump installation requires the following conventional and special equipment and tools:

a) Lifting equipment with suitable and safe load capacity.

b) A steel shim or wedge must be provided at each anchor bolt for leveling the base.

a) The grouting material must be non-shrinking grouting material. A wooden box is required for grouting, and a funnel is required.

d) In order to install and remove the packing, a set of special tools are needed, such as a clamp with hooks.

 

boiler feed pump

Related Pump Knowledge
More Pump Knowledge
27 Apr 2024
            When the O-ring of the multistage pump is damaged or aged, it needs to be replaced in time to ensure the nor...
Read more
20 Apr 2024
           Multistage centrifugal pump vs single-stage centrifugal pump: Which is more efficient? For this problem, the centrifugal pump professional ...
Read more
13 Apr 2024
            Centrifugal pump and axial flow pump are two commonly used pump classes, they have a wide range of applications in industry. Although they...
Read more
07 Apr 2024
         The main function of the feed pump is to lift the deoxygenated water from the water tank or other water storage equipment and transport it in...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.