Wear-resistant mining multi-stage pumps are not uncommon in our production and life, and are a kind of pump with a very wide range of applications. After a period of use and work, wear-resistant mining multi-stage pumps often have some small failures. We must pay attention to such small failures, otherwise the service life of the pump will be greatly reduced. What are the causes of our common problems?   


A. Increased vibration   
1. Rotor imbalance   
2. Bearing wear   
3. The shelf parts are loose   
4. Poor alignment between pump shaft and prime mover shaft   

B. Low flow and range   
1. There is gas in the pump body or suction pipe   
2. The pipeline is blocked   
3. The direction of rotation is wrong   

C. The temperature is too high   
1. The rotating part is unbalanced   
2. Bearing wear   
3. The cooling effect of the bearing becomes worse   
4. Bearing installation error   

D. The seal leaks seriously   
1. Loose packing   
2. The mechanical seal is damaged   
3. Improper sealing fluid pressure   
4. Poor alignment between pump shaft and prime mover shaft   

These minor faults are extremely common in our use of wear-resistant mining multi-stage pumps. Eliminating these minor faults is of great significance to the maintenance of the pump.

Related Pump Knowledge
More Pump Knowledge
25 Oct 2025
      There are multiple causes of cavitation in split case pumps, and there are also many corresponding treatment methods. The followi...
Read more
18 Oct 2025
      Self-balancing multistage pumps are widely used in various industrial scenarios due to their efficient and stable performance. Ho...
Read more
07 Oct 2025
      The petrochemical industry is a crucial pillar industry of the national economy, involving a large amount of fluid transportation...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Email
Chat online
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.