Vibration is an important indicator to evaluate the reliability of the pump unit. Exceeding the standard vibration can cause vibration of the motor and pipeline, forming vibration noise, causing loose connection of the pipe fittings and valves, damage to the motor and motor bearings, and even a serious brewing machine. The tragedy of ruining people.

Common causes and solutions for vibrations in pump operation:

1. Concentricity: The difference between the pump and the motor shaft is an important cause of vibration. Concentricity should be adjusted, preferably using professional tool adjustments such as dial gauges.

2. Gas: There is gas in the pump chamber or pipe. Exhaust the air through the pump exhaust valve and the end of the pipeline, check whether the connection bolts on the sealing surfaces of the water pump and the inlet pipe are loose, whether the gasket is damaged, and whether the pump body and piping system parts are damaged.

3. The support is unstable. Loose pump bases or anchor bolts are common causes of vibration. The bolts must be tightened to avoid looseness.

4. The shaft is bent or the impeller is unbalanced. The impeller friction or the flow passage blockage causes vibration. The impeller balance should be adjusted and the shaft bent to replace the pump shaft.

5. The bearing runs outside the circle. The bearing housing is worn, and the bearing runs out of the eccentric vibration. In this case, only the bearing housing can be replaced, and the bearing is useless.

Related Pump Knowledge
More Pump Knowledge
08 Nov 2025
      Horizontal split-case pumps are commonly used water pumps. During operation, the following issues may occur, causing the pump to ...
Read more
01 Nov 2025
      Many users encounter a tricky issue when operating horizontal multistage centrifugal pumps: the motor runs normally, but no water flows out of t...
Read more
25 Oct 2025
      There are multiple causes of cavitation in split case pumps, and there are also many corresponding treatment methods. The followi...
Read more
18 Oct 2025
      Self-balancing multistage pumps are widely used in various industrial scenarios due to their efficient and stable performance. Ho...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Email
Chat online
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.