Maintenance of pipeline centrifugal pump
1. Maintenance during operation:
(1) The inlet pipe must be filled with liquid, and it is forbidden to run the pump for a long time under cavitation.
(2) Regularly check the motor current, and it must not exceed the motor's fixed current.
(3) After the pump has been running for a long time, if the noise and vibration of the unit increase due to mechanical wear, the unit should be shut down for inspection. If necessary, the vulnerable parts and bearings can be changed. The overhaul period of the unit is generally one year.


2. Maintenance of mechanical seal:
(1) Mechanical seal lubrication should be clean and free of solid particles.
(2) The mechanical seal is strictly prohibited to work under dry grinding conditions.
(3) Rotate the pump (motor) for a few turns before starting to avoid breaking and damage to the graphite ring due to sudden starting.
(4) The leakage tolerance of the seal is 3 drops/min. Otherwise it should be checked.


Working conditions of pipeline centrifugal pump:
1. The suction pressure is ≤1.6MPa, or the maximum working pressure of the pump system is ≤1.6MPa, that is, pump suction inlet pressure + pump head ≤1.6MPa, and the pump static pressure test pressure is 2.5MPa. Please specify the system working pressure when ordering. When the working pressure of the pump system is greater than 1.6MPa, it should be separately stated when ordering, so that the flow-through part and the connection part of the pump are made of cast steel during manufacturing.
2. Ambient temperature <40℃, relative humidity <95%.
3. The volume content of solid particles in the conveyed medium does not exceed 0.1% of the unit volume, and the particle size is less than 0.2mm.
Note: If the medium used is with fine particles, please specify when ordering so that the manufacturer can use wear-resistant mechanical seals.

Related Pump Knowledge
More Pump Knowledge
25 Oct 2025
      There are multiple causes of cavitation in split case pumps, and there are also many corresponding treatment methods. The followi...
Read more
18 Oct 2025
      Self-balancing multistage pumps are widely used in various industrial scenarios due to their efficient and stable performance. Ho...
Read more
07 Oct 2025
      The petrochemical industry is a crucial pillar industry of the national economy, involving a large amount of fluid transportation...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Email
Chat online
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.