1. Maintenance during operation:
(1) The inlet pipe must be filled with liquid, and it is forbidden to run the pump for a long time under cavitation.
(2) Regularly check the motor current, and it must not exceed the motor's fixed current.
(3) After the pump has been running for a long time, if the noise and vibration of the unit increase due to mechanical wear, the unit should be shut down for inspection. If necessary, the vulnerable parts and bearings can be changed. The overhaul period of the unit is generally one year.


2. Maintenance of mechanical seal:
(1) Mechanical seal lubrication should be clean and free of solid particles.
(2) The mechanical seal is strictly prohibited to work under dry grinding conditions.
(3) Rotate the pump (motor) for a few turns before starting to avoid breaking and damage to the graphite ring due to sudden starting.
(4) The leakage tolerance of the seal is 3 drops/min. Otherwise it should be checked.


Working conditions of pipeline centrifugal pump:
1. The suction pressure is ≤1.6MPa, or the maximum working pressure of the pump system is ≤1.6MPa, that is, pump suction inlet pressure + pump head ≤1.6MPa, and the pump static pressure test pressure is 2.5MPa. Please specify the system working pressure when ordering. When the working pressure of the pump system is greater than 1.6MPa, it should be separately stated when ordering, so that the flow-through part and the connection part of the pump are made of cast steel during manufacturing.
2. Ambient temperature <40℃, relative humidity <95%.
3. The volume content of solid particles in the conveyed medium does not exceed 0.1% of the unit volume, and the particle size is less than 0.2mm.
Note: If the medium used is with fine particles, please specify when ordering so that the manufacturer can use wear-resistant mechanical seals.

Related Pump Knowledge
More Pump Knowledge
02 May 2025
             With the rapid advancement of industrial development, multistage centrifugal pumps are increasingly wi...
Read more
25 Apr 2025
          There could be many reasons why a horizontal double-suction centrifugal pump fails to draw water. The following are...
Read more
17 Apr 2025
            In the modern industrial equipment system, multistage centrifugal pumps, as core fluid transfer devices, are...
Read more
09 Apr 2025
          In the mining industry, one of the pumps frequently used in mines is the slurry pump. This is a type of pump capabl...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Email
Chat online
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.