EN CN
Home / Services / Pump Encyclopedia / Pump Knowledge / Eliminate the failure of no water after the axial flow pump is started

Eliminate the failure of no water after the axial flow pump is started

18 Dec 2021Email

The reasons for the failure of the axial flow pump without water are as follows:

   1. The water pump is reversed.

   2. the speed of the water pump is too low.

   3. The impeller of the water pump is loose or reversed.

   4. A large amount of debris is wrapped around the impeller blades of the water pump.

   5. The water pump shaft trips or breaks.

   6. ​​The water lift pipe is leaking seriously.

   7. The submerged depth of the pump impeller is not enough.

   8. The installation head of the pump exceeds the total head of the pump, or the dynamic water level drops beyond the allowable range.

   9. When used in winter, the water in the pipeline freezes.

axial flow pump

↑Click on the pic above to learn 【axial flow pump】products, prices, parameters etc.↑


 The maintenance method for the axial flow pump without water is as follows:

  1. Adjust the rotation direction of the water pump according to the type of power machine used by the water pump.

  2. According to the different forms of the power machine adopted by the water pump, increase the speed separately.

  3. Check the working status of the impeller after disassembly. If the impeller is loose, the impeller should be reset and tightened; if the direction of the impeller is reversed, the impeller should be reinstalled according to the assembly process requirements of the impeller, and attention should be paid to tightening to prevent loosening.

  4. Stop first, and take the method of backwater flushing to remove entangled debris. If the fault cannot be eliminated or the entanglement debris is not completely removed, the axial flow pump should be disassembled and overhauled to remove the entanglement debris on the impeller blades.

   5. Perform maintenance after disassembly. If the water pump shaft has tripped, the water pump shaft should be reinstalled in accordance with the assembly process requirements of the axial flow pump; if the water pump shaft is broken, the water pump shaft should be repaired or replaced.

  6. ​​Find out the specific leaking parts of the water pipe of the axial flow pump, and repair or replace them according to the specific conditions.

  7. Appropriately lower the installation height of the water pump and reinstall the water pump.

   8. Properly increase the speed of the water pump, increase the number of impeller stages, or replace the supporting power machine with a larger power.

   9. First, clear the icing in the water pump pipeline, and then start the machine.

Related Pump Knowledge
More Pump Knowledge
13 Apr 2024
            Centrifugal pump and axial flow pump are two commonly used pump classes, they have a wide range of applications in industry. Although they...
Read more
07 Apr 2024
         The main function of the feed pump is to lift the deoxygenated water from the water tank or other water storage equipment and transport it in...
Read more
01 Apr 2024
          Recently, the design institute consulted to my company's industrial cooling water circulation system used in the co...
Read more
25 Mar 2024
Large displacement pump type           Large displacement pump, as the name suggests, is a pump with a very large flow, and ...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.