Why centrifugal pump start need to close the outlet gate valve?

24 Jun 2019Email

Why does the centrifugal pump start to close the outlet gate valve? Let us explain this reason today.

 

The centrifugal pump is generally driven by an electric motor, and the pump body and the suction line are filled with liquid before starting the pump. When the impeller rotates at a high speed, the impeller drives the liquid between the blades to rotate together. Due to the centrifugal force, the liquid is swept from the center of the impeller to the outer edge of the impeller (the flow rate can be increased to 15 to 25 m/s), and the kinetic energy is also increased. When the liquid enters the pump casing, the flow velocity in the volute casing gradually expands, the liquid flow rate gradually decreases, and a part of the kinetic energy is converted into static pressure energy, so that the liquid flows out along the discharge port with a higher pressure. At the same time, a certain vacuum is formed at the center of the impeller due to the liquid being pumped out, and the pressure Pa at the liquid level is higher than the center of the impeller. Therefore, the liquid in the suction line enters the pump under the pressure difference. The impeller rotates continuously, and the liquid is continuously sucked in and out. Since the centrifugal pump is capable of transporting liquid, mainly by the action of centrifugal force, it is called a centrifugal pump. So, what are the reasons for the centrifugal pump to start after closing the outlet valve?

 

Since the pump motor is in the starting phase, its rotor speed is from slow to fast, reaching the rated value, and its stator current is from large to small, reaching normal current. The starting current of the pump motor is generally up to 4 to 7 times the rated operating current value. In order to operate safely, it is necessary to try to start the motor under light load conditions, and then add the load to the rated value after entering normal operation. When the pump is started, the flow power is determined to be about 1/3, so that the maximum current can be avoided, so the centrifugal pump closes the valve to start. After the standby group speed is stable, open the valve, the opening time should be as short as possible, generally no more than 3 to 5 minutes, otherwise the friction inside the pump will cause damage to the pump parts.

Related Pump Knowledge
More Pump Knowledge
02 May 2025
             With the rapid advancement of industrial development, multistage centrifugal pumps are increasingly wi...
Read more
25 Apr 2025
          There could be many reasons why a horizontal double-suction centrifugal pump fails to draw water. The following are...
Read more
17 Apr 2025
            In the modern industrial equipment system, multistage centrifugal pumps, as core fluid transfer devices, are...
Read more
09 Apr 2025
          In the mining industry, one of the pumps frequently used in mines is the slurry pump. This is a type of pump capabl...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Email
Chat online
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.