EN CN
Home / Services / Pump Encyclopedia / Pump Knowledge / The function of mechanical seal sealing water of circulating feed water pump

The function of mechanical seal sealing water of circulating feed water pump

03 Dec 2020Email

The function of mechanical seal sealing water of circulating feed water pump

 

 

(1) Although the high-pressure water in the circulating feed water pump passes through the seal, it still has a certain pressure. In order to prevent the water in the feed pump from leaking through the gap between the shaft and the seal, it is removed from the condensate pump outlet or demineralized water. The main pipe uses water as sealing water.

 

Circulating feed water pump

 

  (2) The water in the circulating feed water pump is water with a certain temperature. The high-temperature water transfers heat to the bearing through the pump shaft or the metal of the pump body, which increases the bearing temperature. In order to control the heat transfer, the sealing water also plays a cooling role.

 

(3) When the sealing water passes through the seal, the water forms a water film between the shaft and the seal to prevent the gap between the shaft and the seal from leaking, causing a large amount of working fluid loss; at the same time, high temperature feed water will pass through The pump shaft and pump body metal transfer heat to the bearing to increase the bearing temperature. In severe cases, the bearing will be burnt; the gap between the high-speed rotating shaft and the seal is very small. When the sealing water is lost, the water film here is also destroyed, and the shaft and the seal are likely to be rubbed. The vibration of the water pump increases, which will cause equipment damage in severe cases. The return water of the sealing water is generally introduced into the condenser with a multi-stage water sealing pipe.

Related Pump Knowledge
More Pump Knowledge
30 Sep 2025
       During the operation of a multistage pump, if the balance disk clearance is not properly adjusted, problems such as shaft runout, excessive vib...
Read more
23 Sep 2025
       A sudden water leak in a multistage centrifugal pump is really annoying, especially when you watch the water stain spread. Don't rush to disass...
Read more
12 Sep 2025
         During the operation of split-case pumps, a decline in efficiency is a relatively common issue,This not only affects...
Read more
05 Sep 2025
       The causes and treatment methods for insufficient pressure in multistage pumps can be analyzed and resolved from multiple perspectives. As a se...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Email
Chat online
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.