EN CN
Home / Services / Pump Encyclopedia / Pump Technique / Steps for single test of high efficiency and energy saving self-balancing multistage centrifugal pump

Steps for single test of high efficiency and energy saving self-balancing multistage centrifugal pump

23 Dec 2020Email

Steps for single test of high efficiency and energy saving self-balancing multistage centrifugal pump

 

 

   After the installation of the high-efficiency and energy-saving self-balancing multi-stage centrifugal pump unit and its accessories, a stand-alone test is required. The pump runs for 2 hours on a stand-alone basis. If possible, a load test is carried out.

 

Steps for single test of high efficiency and energy saving self-balancing multistage centrifugal pump

 

  The single machine test of the high-efficiency energy-saving self-balancing multi-stage centrifugal pump is carried out according to the following methods and steps:

 

   1. Check whether the power distribution cabinet meets the requirements and whether the motor wiring terminals meet the product requirements.

 

  2. Remove the key of the motor and water pump coupling to separate the motor from the water pump.

 

  3. Test the motor and check whether the steering and sound are normal.

 

  4. Connect the motor and the water pump with a key, crank the car manually, and check if there is noise when the water pump is rotating.

 

   5. Carry out a spot test on the water pump unit. When there is no water in the water pump, it is not easy to start the water pump for a long time, so as not to damage the bearings of the water pump.

 

   6. Close the outlet valve of the water pump, open the inlet valve, and remove the air in the pump. Start the water pump unit, observe the value of the pressure gauge on the pipeline, and adjust the gate valve of the test pipeline to control the pipeline pressure so that the pipeline pressure reaches the pressure value of the normal operation of the pump.

 

  7. Observe the starting pressure value of the safety valve and adjust the safety valve so that the starting pressure value of the safety valve is 1.1 times the working pressure value of the water pump.

 

   8. Check the valves, pipe fittings, and welds for leakage.

Related Pump Knowledge
More Pump Knowledge
09 Jul 2026
      Horizontal single-stage double-split casing centrifugal pumps are widely applied in various industries and play an indispensabl...
Read more
02 Jul 2026
     As core equipment for high-pressure water supply, industrial pressurization and building water supply and drainage systems, self-balancing multis...
Read more
24 Jun 2026
      The automatic control panel matched with the diesel water pump features strong environmental adaptability. It can withstand mechanical shocks, e...
Read more
17 Jun 2026
      In the field of industrial fluid transportation, double-suction pumps and horizontally split double-suction pumps are vital pumpi...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Email
Chat online
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.