        Split case double suction pumps are widely used in urban water supply and drainage, agricultural irrigation, industrial circulation and other fields by virtue of high efficiency, energy saving, compact structure and other advantages. The core working principle of this type of pump relies on centrifugal force: the motor drives the pump shaft to rotate the impeller at high speed (normally 1450~2900 r/min). Liquid between impeller blades is thrown outward by centrifugal force, forming a high-pressure zone at the impeller outlet and a low-pressure zone at the inlet, so as to realize continuous liquid transportation. As the critical component for torque transmission, the pump shaft of split case double suction pump directly determines the operating efficiency and service life of the pump set. The key points of pump shaft inspection are analyzed below from the perspective of technical specifications:

 

1580796798731982

 

I. Fit Tolerance Requirements of Shafting

  1. Fit tolerance between shaft sleeve and shaft: H7/h6 transition fit is adopted to prevent relative sliding between the shaft sleeve and shaft. The surface roughness of the shaft sleeve shall reach Ra=1.6 μm, complying with the surface finish requirement for wear-resistant parts specified in GB/T 5656-2013 Technical Specification for Shaft Sleeves of Centrifugal Pumps.
  2. Parallelism of keyway to shaft centerline: The parallelism error between the centerline of the centrifugal pump keyway and the shaft centerline shall be controlled within 0.03 mm, to avoid impeller vibration or keyway fracture caused by uneven force transmission.
  3. Shaft bending: The allowable bending of shaft diameter shall not exceed 0.013 mm (low-speed pump) or 0.04 mm (high-speed pump). The maximum bending at the middle of the shaft shall be ≤0.07 mm for low-speed pumps and ≤0.04 mm for high-speed pumps. Dial indicator measurement shall be adopted to ensure the shaft runout is within allowable limits.

II. Inspection Standards for Shaft Surface Quality

  1. Macroscopic defect inspection: The pump shaft surface shall be free of cracks, severe wear, pits and other defects. If the roundness or cylindricity error of the journal exceeds 0.02 mm, or the full-length straightness exceeds 0.05 mm, surfacing repair or replacement is required.
  2. Surface roughness and finish: The surface roughness of the journal shall be Ra≤0.8 μm, and Ra=1.6 μm for the mating surface between shaft sleeve and shaft. The surface hardness shall meet HRC25–35 (carburized steel shaft sleeve) to resist abrasive wear during long-term operation.
  3. Erosion and corrosion protection: For split case double suction pumps handling corrosive media (e.g. chemical wastewater treatment), special attention shall be paid to checking for pitting or intergranular corrosion on the shaft surface. Non-destructive testing methods such as penetrant testing are recommended to detect microcracks.

III. Inspection Procedures

  1. Disassembly and cleaning: After shutdown, remove the pump cover. Thoroughly clean oil stains and impurities on the shaft surface with kerosene or special cleaning agent, and focus on checking looseness at the mating position between impeller hub and shaft.
  2. Data recording and analysis: Record the shaft wear loss (maximum allowable wear ≤3% of nominal diameter), keyway deformation and other data in detail. Combined with pump vibration spectrum analysis (vibration velocity ≤4.5 mm/s), judge the risk of resonance.
  3. Selection of repair process: Chromium plating repair is applicable for minor wear (≤0.1 mm). For severe wear or excessive bending, finish turning of the journal on a CNC lathe is recommended to restore the dimensional tolerance to H7 fit grade.

IV. Operation and Maintenance Recommendations

It is recommended that users establish a preventive-oriented shafting maintenance system: conduct monthly radial runout inspection of shafting, quarterly keyway stress testing, and annual shafting dynamic balance verification in accordance with API 610 standard. Strictly control motor speed fluctuation (≤±5% of rated speed) during operation to avoid additional stress on shafting caused by sudden torque change. Compliance with the above technical specifications can extend the mean time between failures (MTBF) of split case double suction pumps to more than 8000 hours and greatly reduce the whole life cycle cost of equipment.

 

Related Pump Knowledge
More Pump Knowledge
09 Jul 2026
      Horizontal single-stage double-split casing centrifugal pumps are widely applied in various industries and play an indispensabl...
Read more
19 Jan 2026
      As a core fluid transfer equipment, the single-stage double-suction split case centrifugal pump is widely used in water conservan...
Read more
25 Oct 2025
      There are multiple causes of cavitation in split case pumps, and there are also many corresponding treatment methods. The followi...
Read more
Related Products
More
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Email
Chat online
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.