Specification for installation of boiler feed water pump

02 Mar 2021Email

Boiler feed water pumps are widely used in the power sector, thermal power plants require a large number of boiler feed water pumps, condensate pumps, circulating water pumps, ash and slag liquid pumps, etc. for boiler steam system make-up water; in the mining and metallurgical industries, such as underground mines In the process of drainage, beneficiation, smelting, and rolling, it is necessary to use the boiler feed water pump to supply water. So, what is the installation specification of the boiler feed water pump, let's briefly talk about it.

Specification for installation of boiler feed water pump

   Technical specification for installation and operation of boiler feed water pump:

1. When installing the boiler feedwater pump, avoid bearing the weight of the pipeline on the boiler feedwater pump. The anchor bolts or expansion bolts need to be fully tightened during installation and checked within a certain period of time to prevent loosening and vibration. .

  2. When installing the boiler feedwater pump, install the inlet and outlet pipe connections first, and then fix the anchor bolts of the boiler feedwater pump. This installation sequence can avoid tensile stress during installation and corresponding damage to the pump. In principle, the installation of valves and soft connections (shock absorbers) can facilitate the later maintenance of the boiler feedwater pump, and in order to reduce pipeline resistance and transmission efficiency, the piping must be slightly larger than the inlet and outlet of the boiler feedwater pump. (When the diameter of the inlet pipe is larger than the diameter of the boiler feed water pump, an eccentric reducing pipe should be installed. The plane position of the pipe is up and the slope is down to prevent air from collecting in the pipe. Similarly, when the pipe diameter is connected, A section of straight pipe is equipped at the inlet, the length of the straight pipe is more than 2~3 times the diameter of the pipe)

  3. Before installing the boiler feed water pump, consider the rationality of the installation location. *To meet the suction vacuum height requirements of the boiler feed water pump, if the conditions cannot meet the needs of the boiler feed water pump, the equipment must be adjusted before installation. The second boiler feed water pump and the boiler feed water pump, the boiler feed water pump and the pump house Keep a reasonable location space between them, which is convenient for maintenance and other installation items. Third, for special boiler feed water pumps, you need to pay attention to its installation precautions. You can install it after reading and understanding. Fourth, for problems that may occur naturally or unnaturally at the installation location, such as noise, leakage, vibration, etc., it is necessary to do a good job of isolation, heat preservation, and sewage before installation.

4. Before connecting the boiler feed water pump to the pipeline, carefully check whether there are sundries in the boiler feed water pump pump body, such as wires, installation tools, packaging materials or other hard objects, and remove them in time to avoid affecting the boiler feed water pump after the pump is turned on. Quality and damage.

5. During the installation of the boiler feed water pump, in order to facilitate maintenance and safe use, the inlet of the boiler feed water pump is equipped with a regulating valve, and the outlet is equipped with a pressure gauge and valve to ensure that the boiler feed water pump is in the best working condition. run. For boiler feedwater pumps with a higher Yangcheng level, a one-way check valve is installed before the outlet valve to prevent the boiler feedwater pump from being damaged by water hammer when the boiler feedwater pump suddenly shuts down, thereby increasing the service life of the boiler feedwater pump.

6. If the transport medium contains debris, the debris can easily enter the pump body and damage the internal structure of the boiler feed water pump, and it is easy to block the outlet pipe, which will cause great difficulties in future maintenance. Therefore, it should be in the boiler feed water pump. Install filters, filters, etc. at the entrance to avoid similar situations.

  7. For the installation of boiler feedwater pumps that require suction height, strict requirements must be imposed on the inlet of the boiler feedwater pump. First of all, consider whether the performance of the boiler feedwater pump meets the installation requirements, and also consider the height drop caused by the drop in the liquid level after the boiler feedwater pump runs. The inlet pipe of the boiler feed water pump must be leak-free, air-tight, with fewer elbows, and minimized in length. For boiler feed water pumps that do not have self-priming capability, it is also necessary to consider the installation of foot valves, filters, filter screens and other factors.

   8. The basic problem of the boiler feed water pump is to ensure that the contact surface of the boiler feed water pump is kept level. The position and size of the reserved hole are determined according to the actual size of the boiler feed water pump. When using vibration isolators or cushions, the dynamic and static load of the boiler feed water pump must be fully considered.

   9. For environmental considerations, when the boiler feed water pump is installed, it must be equipped with a rain cover or a simple canopy to avoid damage caused by external factors.

Related Pump Knowledge
More Pump Knowledge
11 May 2024
The role of boiler feed pump in thermal power plant          In the operation of thermal power plant, boiler feed pump plays a crucial role. Its core...
Read more
04 May 2024
           There is a close relationship between the flow, head and efficiency of the pump, which together determine the...
Read more
27 Apr 2024
            When the O-ring of the multistage pump is damaged or aged, it needs to be replaced in time to ensure the nor...
Read more
20 Apr 2024
           Multistage centrifugal pump vs single-stage centrifugal pump: Which is more efficient? For this problem, the centrifugal pump professional ...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.