   Horizontal water pump has the characteristics of high efficiency, wide performance range, safe and stable operation, low noise, long life, convenient installation and maintenance, etc. For transporting clean water or other liquids with physical and chemical properties similar to water. It can also be used to transport hot water, oil, corrosive or abrasive media by changing the material and sealing form of the pump's flow-through components and adding a cooling system.

 

 

 

  Pipeline connection precautions during installation of horizontal water pump:

 

Horizontal water pumps are also widely used in many fields. Because their cost is relatively low compared with multi-stage pumps, they play an important role in various industries. However, sometimes the user chooses to install the pipeline during the installation process. The pump performance parameters have a certain influence.

 

After the suction and delivery pipes of the centrifugal pump are connected straight (as far as possible), the joint surface between the centrifugal water pump and the pipeline should be ensured good airtightness, especially the water inlet pipeline. There should be no possibility of trapping air.

 

Note: The suction pipe of the centrifugal pump should be installed separately for each centrifugal pump, and the pipes of the horizontal multistage centrifugal pump should be as short as possible, and the number of elbows should be small to avoid sudden turns. The elbows and connecting pipes should be 90° or greater and bend. The location should be as smooth as possible and not too close to the inlet of the centrifugal water pump; the horizontal multi-stage centrifugal pump should be installed with a slight downward slope against the direction of the water flow to prevent air pockets. It is best to use a tapered eccentric reducer.

 

   When installing the centrifugal pump pipeline, especially the inlet pipeline, the pipeline welding slag, rust and dirt should be removed. The inlet and outlet pipes of the centrifugal water pump should be fixed with brackets, and the flange of the water pump should not be broken by excessive tension, and the vibration of the horizontal multi-stage centrifugal pump caused by the vibration of the water pump pipe should also be avoided.

 

   Flexible joints should be installed on the inlet and outlet pipes of the pump to reduce the impact of pipeline stress on the pump and reduce the transmission of vibration between the pump and the pipeline.

 

Centrifugal pump suction pipe: when pumping water from the pool, the length of the straight pipe section in front of the suction port of the centrifugal pump should not be less than 3 times the diameter of the inlet, and the depth of the suction pipe of the centrifugal pump should be greater than 1.5 times the diameter of the inlet. Less than 500mm. The distance between the suction pipe of the pump and the pool wall should be greater than 1.5 times the diameter, and the distance from the bottom of the pool should be 1.5 times the diameter and not less than 500mm, and a filter should be installed. The total product of the filter should not be less than 2 of the area of ​​the suction pipe. 

Related Pump Knowledge
More Pump Knowledge
14 Aug 2025
        Double-suction centrifugal pumps (also known as split-case pumps), with their characteristics of high efficiency and stabi...
Read more
07 Aug 2025
       In mining and coal preparation operations, the transportation of high-concentration slurry has always been a key factor res...
Read more
31 Jul 2025
      The self-balancing multistage centrifugal pump is the next evolutionary step from the classic D-type horizontal multistage design...
Read more
24 Jul 2025
      In our daily life, pumps are indispensable in many places. For example, the tap water in our homes is delivered from water plants...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Email
Chat online
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.