EN CN
Home / Services / Pump Encyclopedia / Pump Knowledge / Pneumatic diaphragm pumps operation tips

Pneumatic diaphragm pumps operation tips

24 Sep 2020Email

Pneumatic diaphragm pumps operation tips

 

 

Pneumatic diaphragm pump is a positive displacement pump that uses compressed air as its power to change the volume through the reciprocating deformation of the diaphragm. Its working principle is similar to that of a plunger pump.

Pay attention to the following points when using a pneumatic diaphragm pump:

1. Ensure that the largest particle contained in the fluid does not exceed the maximum safe particle diameter standard of the pump.

 

 

2. The inlet pressure should not exceed the maximum allowable working pressure of the pump. Compressed air higher than the rated pressure may cause personal injury and property loss and damage the performance of the pump.

 

 

3. Ensure that the pump pressure piping system can withstand the highest output pressure reached, and ensure the clean and normal working conditions of the driving air system.

 

 

4. Electrostatic sparks may cause explosions and cause personal injury and death accidents and property losses. If necessary, use a wire with a large enough cross-sectional area to properly and reliably ground the ground screw on the pump.

 

 

5. Grounding requirements comply with local laws and regulations and some special requirements on site.

 

 

6. Tighten the pump and all connecting pipe joints to prevent electrostatic sparks from being generated by vibration and impact. Use antistatic hose.

 

 

7. To periodically check and test the reliability of the grounding system, the grounding resistance is required to be less than 100 ohms.

 

 

8. Keep good exhaust and ventilation, away from flammable, explosive and heat sources.

 

 

9. The exhaust of the pump may contain solids. Do not point the exhaust to the working area or people to avoid personal injury.

 

 

10. When the diaphragm fails, the conveyed materials will be ejected from the exhaust muffler.

 

 

11. When transporting flammable and toxic fluids, please connect the outlet to a safe place away from the work area.

 

 

12. Please use pipes with at least 3/8" inner diameter and smooth inner wall to connect the exhaust port and the muffler.

 

 

13. The high pressure of the fluid may cause serious personal injury and property damage. Please do not apply pressure to the pump and the material pipe when the pump is pressurized. When performing any maintenance work on the system, if you want to do maintenance, first cut off the air intake of the pump, open the bypass pressure relief mechanism to relieve the pressure of the pipeline system, and slowly loosen the connected pipeline joints.

 

 

14. If the transportation is harmful. Toxic fluid pump, please do not send the pump directly to the manufacturer for repair. Properly dispose of it in accordance with local laws and regulations, and use Shanghai Wangquan Pump Industry Co., Ltd. genuine accessories to ensure its service life.

 

 

15. The liquid transportation part uses aluminum alloy pumps, please Do not use to transport liquids containing Fe3+, halogenated hydrocarbons and other halogenated hydrocarbon solvents, which will cause corrosion and cause the pump body to burst.

 

 

16. Ensure that all parts contacting the transport body will not be corroded and damaged by the transported fluid.

 

 

17. Ensure that all operators are familiar with the operation and use of the pump and master the safety precautions for the use of the pump. If necessary, provide necessary protective equipment.

 

 

18. Use the pump correctly and do not allow long-term idling.

Related Pump Knowledge
More Pump Knowledge
16 Mar 2026
      Combining equipment characteristics and practical operating experience, the clearance adjustment of the balance drum and balance ...
Read more
09 Mar 2026
     As a fluid delivery equipment widely used in industrial fields, the performance stability of multistage centrifugal pumps is criti...
Read more
28 Feb 2026
      The head of a centrifugal pump is closely related to the pressure in the pipeline, and directly affects the flow state and delive...
Read more
20 Feb 2026
     The MD type wear-resistant multistage centrifugal pump for coal mines is independently developed by Changsha Zoomlian Pump Industry. It possesses...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Email
Chat online
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.