EN CN
Home / Services / Pump Encyclopedia / Pump Knowledge / Multistage pump mechanical seal's precautions and maintenance

Multistage pump mechanical seal's precautions and maintenance

27 May 2019Email

1. The multistage pump should first drive the pump motor several times before starting to avoid the graphite ring breakage caused by sudden movement;

2. Seal leakage tolerance 3 drops / MIN, otherwise it should be overhauled;

3. Mechanical seal lubrication should be cleaned without solid particles;

4. It is strictly forbidden to work mechanical seals under dry grinding conditions.

Three major maintenance points for multistage pumps in operation:

1. The inlet pipe must be filled with liquid, and the pump is prohibited from running for a long time under cavitation.

2. Check the motor current value regularly, and do not exceed the rated current of the motor.

3. After long-term operation of multistage pump, due to mechanical wear, when the noise and vibration of the unit increase, it should be stopped to check and replace the wearing parts if necessary. The overhaul period of the unit is generally one year.

Related Pump Knowledge
More Pump Knowledge
26 Jan 2026
       The multistage centrifugal pump is a type of pumping equipment widely used in water conservancy, electric power, chemical industry and other fi...
Read more
19 Jan 2026
      As a core fluid transfer equipment, the single-stage double-suction split case centrifugal pump is widely used in water conservan...
Read more
12 Jan 2026
      In industrial fluid transfer applications, the stable operation of multistage pumps is of critical importance. However, in practi...
Read more
05 Jan 2026
         Centrifugal pumps are widely used in industrial fluid transportation systems. However, water pressure fluctuations d...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Email
Chat online
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.