The multi-stage inline pump design uses a single-end mechanical seal. It should be noted that the mechanical seal has many shortcomings such as high number of parts, high precision, high installation and disassembly requirements, and corresponding high cost. However, from the point of view of actual needs and production, the advantages and disadvantages of using mechanical seals, mechanical seals are also the future development trend.

       1) Main sealing original: composed of moving ring and static ring. The moving ring and the stationary ring are generally made of different materials, one having a lower hardness and one having a higher hardness. However, it is also possible to make the two rings of the same material as the case may be.

       2) Auxiliary sealing original: It consists of moving ring seal ring, static ring seal ring and other suitable gaskets. Depending on the requirements, the auxiliary seals are often O-rings, V-rings or other shaped seal rings. In order to absorb vibrations that have a bad influence on the sealing surface, the auxiliary sealing ring is usually made of rubber or plastic.

       3) Pressing the original and other auxiliary originals: such as springs, push rings, transmission seats, anti-rotation pins, etc., as well as other parts necessary to ensure the working of the moving ring and the stationary ring, belong to this type of original. Due to the complicated working conditions of the mechanical seal, frictional heat is continuously generated on the moving ring and the static ring sealing surface during operation, resulting in vaporization of the liquid film between the moving ring and the stationary ring, and aging, coking and deformation of some parts affect the service life. . Therefore, when selecting a mechanical seal, you must also pay attention to the cooling of the mechanical seal.

Related Pump Knowledge
More Pump Knowledge
11 May 2024
The role of boiler feed pump in thermal power plant          In the operation of thermal power plant, boiler feed pump plays a crucial role. Its core...
Read more
04 May 2024
           There is a close relationship between the flow, head and efficiency of the pump, which together determine the...
Read more
27 Apr 2024
            When the O-ring of the multistage pump is damaged or aged, it needs to be replaced in time to ensure the nor...
Read more
20 Apr 2024
           Multistage centrifugal pump vs single-stage centrifugal pump: Which is more efficient? For this problem, the centrifugal pump professional ...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.