First, the bearing temperature standard - pump bearing temperature standard

1. GB3215-82 4.4.1 During the operation of the pump, the maximum temperature of the bearing does not exceed 80 °C

2. JB/T5294-91 3.2.9.2 The temperature rise of the bearing shall not exceed the ambient temperature of 40, and the maximum temperature shall not exceed 80 °C.

3. JB/T6439-92 4.3.3 When the pump is running under the specified working conditions, the temperature of the outer surface of the built-in bearing should not be higher than the temperature of the conveying medium by 20 °C, and the maximum temperature is not higher than 80 °C. The external surface temperature rise of the externally mounted bearing should not be higher than the ambient temperature of 40 °C. The maximum temperature is not higher than 80 °C

4. JB/T7255-94 5.15.3 The operating temperature of the bearing. The bearing temperature rise must not exceed the ambient temperature of 35 °C, the maximum temperature must not exceed 75 °C

5, JB/T7743-95 7.16.4 Bearing temperature rise must not exceed the ambient temperature of 40 ° C, the maximum temperature must not exceed 80 °C

6. JB/T8644-1997 4.14 The temperature rise of the bearing shall not exceed the ambient temperature of 35 °C, and the maximum temperature shall not exceed 80 °C.

Second, the motor bearing temperature regulations, the cause of abnormalities and treatment

The regulations stipulate that the maximum temperature of the rolling bearing does not exceed  95 °C, and the maximum temperature of the sliding bearing does not exceed 80 °C. And the temperature rise does not exceed 55 ° C (temperature rise is the bearing temperature minus the ambient temperature at the test).

(1) Cause: The shaft is bent and the center line is not allowed. Handle; find the center again.

(2) Reason: The basic screw is loose. Handling: Tighten the foundation screws.

(3) Reason: The lubricating oil is not clean. Handling: Replace the lubricant.

(4) Reason: The lubricating oil has been used for a long time and has not been replaced. Treatment: Wash the bearings and replace the lubricant.

(5) Cause: The ball or roller in the bearing is damaged.

Handling: Replace the new bearing. In accordance with national standards, F-class insulation B-level assessment, motor temperature rise control at 80K (resistance method), 90K (component method). Considering the ambient temperature of 40 °C, the maximum operating temperature of the motor should not exceed 120/130 °C.

The bearing temperature is up to 95 degrees. The temperature of the outdoor surface of the bearing is measured by an infrared detecting gun. Empirically, the maximum temperature of the 4-pole motor cannot exceed 70 °C. For the motor body, no monitoring is required. After the motor is manufactured, in general, temperature rise is basically fixed and will not change or grow with the motor operation. The bearing is a consumable part and needs to be tested.

Related Pump Knowledge
More Pump Knowledge
27 Apr 2024
            When the O-ring of the multistage pump is damaged or aged, it needs to be replaced in time to ensure the nor...
Read more
20 Apr 2024
           Multistage centrifugal pump vs single-stage centrifugal pump: Which is more efficient? For this problem, the centrifugal pump professional ...
Read more
13 Apr 2024
            Centrifugal pump and axial flow pump are two commonly used pump classes, they have a wide range of applications in industry. Although they...
Read more
07 Apr 2024
         The main function of the feed pump is to lift the deoxygenated water from the water tank or other water storage equipment and transport it in...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.