 The overhaul of the double-suction pump also includes the cleaning of the parts. Next, let's take a look at how the cleaning and inspection of each part needs to be done:

       1. Clean the impeller and impeller ring and check the cavitation, crack and wear of the impeller blades. The cavitation must be replaced. If you can continue to use it, you don't have to remove it from the shaft, because it is difficult to disassemble under normal circumstances. If it is not necessary to remove it, it must be disassembled with special tools and heated while disassembling.

       2. Clean the pump shaft of the double suction pump, repair the thread and keyway, and check the wear of the pump shaft.

       3. Clean the shaft sleeves on both sides of the pump, and measure the size of the machine seal. Use the hexagonal wrench to loosen the seal ring of the machine seal and remove the static ring and spring seat. The static and dynamic rings should be free of defects such as wear and cracks, otherwise the springs should be cleaned. The elasticity should be good without plastic deformation and rust. The machine seal bushings have no wear and groove marks. Replace the machine seal “O” rubber ring and bushing rubber ring.

       4. Use kerosene to soak and clean the rolling bearing. There should be no defects such as abrasion, corrosion, and ball bearing rupture; if the bearing is rotated by hand, the bearing rotation should be flexible, no abnormal sound and vibration, otherwise the bearing should be replaced.

       5. Clean and inspect the wheel and flat key. There is no wear, aging or crack on the rubber ring of the wheel, otherwise it will be replaced.

       6. Clean the seal ring on both sides of the pump and the spacer sleeve (the packing sleeve), the bearing chamber, the cooling water pipe and the air pump.

       7. Clean the pump casing joint surface, cooling water tank, seal ring groove, and mechanical seal chamber.

       8. Clean all the screws in the double suction pump and repair the damaged thread buckle; repair the parts and other defects such as scratches and grooves.

Related Pump Knowledge
More Pump Knowledge
30 Sep 2025
       During the operation of a multistage pump, if the balance disk clearance is not properly adjusted, problems such as shaft runout, excessive vib...
Read more
23 Sep 2025
       A sudden water leak in a multistage centrifugal pump is really annoying, especially when you watch the water stain spread. Don't rush to disass...
Read more
12 Sep 2025
         During the operation of split-case pumps, a decline in efficiency is a relatively common issue,This not only affects...
Read more
05 Sep 2025
       The causes and treatment methods for insufficient pressure in multistage pumps can be analyzed and resolved from multiple perspectives. As a se...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Email
Chat online
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.