EN CN
Home / Services / Pump Encyclopedia / Pump Knowledge / Coupling offset maintenance and measurement adjustment method

Coupling offset maintenance and measurement adjustment method

24 Jun 2019Email

The center of rotation of the two shafts connected to the coupling of the pump and the motor should be strictly concentric. The coupling must be accurately aligned and centered during installation, otherwise it will cause great stress on the coupling. It will seriously affect the normal operation of the shaft, bearings and other parts on the shaft, and even cause vibration or damage to the entire machine and foundation.


When installing a new pump, the verticality between the end face of the coupling and the axis can be left unchecked, but when installing the old pump, be sure to check carefully, and when it is found that the vertical is not vertical, then when looking for the equipment being installed, First, install the driven machine (pump) so that its axis is in the horizontal position, and then install the active machine (motor), so only need to adjust the active machine when looking for the positive, and adjust the surface of the active machine (motor) under the feet. Method to adjust.


Introduce two measurement adjustment methods commonly used in the maintenance process:

 

1) Measuring the different center of the coupling with a knife-shaped ruler and a feeler gauge and measuring the non-parallelism of the end face of the coupling by using a wedge-shaped clearance rail or a feeler gauge. This method is suitable for low-speed, low-precision precision of elastic coupling. device.

 

2) Using the dial gauge and the table or special alignment tool to measure the different center and non-parallel of the two couplings, this method is suitable for rotating equipment with high speed, rigid connection and high precision.

Related Pump Knowledge
More Pump Knowledge
11 Jun 2025
        Can a multistage centrifugal pump automatically absorb water? To answer this question, Zoomlian Pump Industry, a manufacturer of multistage ce...
Read more
04 Jun 2025
           The split-case double-suction pump is a high-flow centrifugal pump, and it is the most frequently used water ...
Read more
28 May 2025
                     In the modern industrial equipment system, self-balancing multistage centr...
Read more
09 May 2025
               Compared with positive displacement pumps, the structure of centrifugal pumps is indeed simpler...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Email
Chat online
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.