EN CN
Home / Services / Pump Encyclopedia / Pump Knowledge / Boiler feed pump disassembly and assembly

Boiler feed pump disassembly and assembly

17 Jun 2019Email

Boiler feed pump removal steps:

       1. The boiler feed water pump is separated from the motor, and the medium is drained (to prevent the motor and toxic medium from injuring people);

       2. Disassemble the boiler pump discharge body;

       3. Disassemble the boiler pump stator, if necessary, according to the pump shaft steering shaft to assist;

       4. Disassemble the rotor and the intermediate shaft;

       5. Disassemble the drive shaft and shaft seal;

       6. Take out the boiler pump bearing and positioning sleeve and take it out from the bearing housing;

       7. The boiler pump that has not been used for a long time should be treated with anti-rust. The method is to apply non-painted metal surface with anti-rust grease, including the shaft surface, the inner cavity of the packing shell, etc., and lubricate.

 

When assembling boiler feed pumps, note the following:

       1. The boiler pump parts should be carefully cleaned and inspected during assembly, and the damaged parts should be replaced;

       2. The correctly installed bearing makes the shaft rotate flexibly and without jamming.

       3. Shaft seal installation: When installing the stuffing box, the packing gland pressing bolt should be placed in the housing installation window to facilitate the wrench to adjust the bolt;

       4, mechanical seal installation should be careful, the friction end face should be cleaned and coated with grease;

       5. When assembling the 20,000-way joint of the drive shaft, check whether the seal ring is damaged or not, and fill the cavity with grease;

       6. When installing the stator, apply lubricant to the surface of the rotor and stator cavity to facilitate stator installation;

       7. When the body pressure is tightened, the nut should be tightened evenly;

       8. When installing and assembling, the coupling installation deviation: △Y≤0.2mm, △α≤30'.

Related Pump Knowledge
More Pump Knowledge
11 May 2024
The role of boiler feed pump in thermal power plant          In the operation of thermal power plant, boiler feed pump plays a crucial role. Its core...
Read more
04 May 2024
           There is a close relationship between the flow, head and efficiency of the pump, which together determine the...
Read more
27 Apr 2024
            When the O-ring of the multistage pump is damaged or aged, it needs to be replaced in time to ensure the nor...
Read more
20 Apr 2024
           Multistage centrifugal pump vs single-stage centrifugal pump: Which is more efficient? For this problem, the centrifugal pump professional ...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.