EN CN
Home / Services / Pump Encyclopedia / Pump Knowledge / Boiler feed pump disassembly and assembly

Boiler feed pump disassembly and assembly

17 Jun 2019Email

Boiler feed pump removal steps:

       1. The boiler feed water pump is separated from the motor, and the medium is drained (to prevent the motor and toxic medium from injuring people);

       2. Disassemble the boiler pump discharge body;

       3. Disassemble the boiler pump stator, if necessary, according to the pump shaft steering shaft to assist;

       4. Disassemble the rotor and the intermediate shaft;

       5. Disassemble the drive shaft and shaft seal;

       6. Take out the boiler pump bearing and positioning sleeve and take it out from the bearing housing;

       7. The boiler pump that has not been used for a long time should be treated with anti-rust. The method is to apply non-painted metal surface with anti-rust grease, including the shaft surface, the inner cavity of the packing shell, etc., and lubricate.

 

When assembling boiler feed pumps, note the following:

       1. The boiler pump parts should be carefully cleaned and inspected during assembly, and the damaged parts should be replaced;

       2. The correctly installed bearing makes the shaft rotate flexibly and without jamming.

       3. Shaft seal installation: When installing the stuffing box, the packing gland pressing bolt should be placed in the housing installation window to facilitate the wrench to adjust the bolt;

       4, mechanical seal installation should be careful, the friction end face should be cleaned and coated with grease;

       5. When assembling the 20,000-way joint of the drive shaft, check whether the seal ring is damaged or not, and fill the cavity with grease;

       6. When installing the stator, apply lubricant to the surface of the rotor and stator cavity to facilitate stator installation;

       7. When the body pressure is tightened, the nut should be tightened evenly;

       8. When installing and assembling, the coupling installation deviation: △Y≤0.2mm, △α≤30'.

Related Pump Knowledge
More Pump Knowledge
09 Jul 2026
      Horizontal single-stage double-split casing centrifugal pumps are widely applied in various industries and play an indispensabl...
Read more
02 Jul 2026
     As core equipment for high-pressure water supply, industrial pressurization and building water supply and drainage systems, self-balancing multis...
Read more
24 Jun 2026
      The automatic control panel matched with the diesel water pump features strong environmental adaptability. It can withstand mechanical shocks, e...
Read more
17 Jun 2026
      In the field of industrial fluid transportation, double-suction pumps and horizontally split double-suction pumps are vital pumpi...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Email
Chat online
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.