       1. How to choose the pressure of the metering pump?

  When choosing a metering pump, it is generally necessary to know the rated pressure, rated flow, type (diaphragm or plunger) and flow material. The rated pressure of the metering pump generally refers to the port pressure. It is generally better to select the rated pressure to exceed 10%-20% of the actual use pressure during the selection. It can save resources, reduce costs, and improve the actual use of the metering pump. Measurement accuracy.

  2. How to choose the flow rate of the metering pump?

  When the metering pump is working, the metering accuracy is generally higher between 10% and 90% of the rated flow. Therefore, when selecting the rated flow, the selected flow should generally be equal to or slightly greater than the flow required by the process.

  3. How to choose the type of metering pump?

      Metering pumps are mainly divided into plunger type and diaphragm type according to different transmission modes. The performance of plunger metering pumps is relatively stable, the metering accuracy is relatively high, and it can transport some relatively high viscosity media. In addition to the advantages, there are some special advantages: there is no leakage during operation, and it can transport special liquids (such as dangerous goods, corrosive liquids, etc.).

Related Pump Knowledge
More Pump Knowledge
21 Aug 2026
      Feed‑water pumps are classified into high‑pressure and low‑pressure types primarily based on their outlet operating pressure. The fundamental re...
Read more
14 Aug 2026
      The core requirements for waterworks circulating water supply systems are straightforward: large flow capacity, continuous stable...
Read more
07 Aug 2026
    Many people wonder why mining multistage pumps must adopt special wear-resistant materials while ordinary multistage pumps can operate w...
Read more
31 Jul 2026
Product Basic Introduction Split Volute Single-stage Double-suction Centrifugal Pump bears relatively small axial force during operation. Howeve...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Email
Chat online
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.