Installation method of single-stage single-suction centrifugal pump

03 Apr 2023Email

The installation and calibration of a single-stage single-suction centrifugal pump are crucial for its operation and service life. Therefore, the installation and calibration must be carried out carefully.

 

Installation and Calibration of Single-stage Single-suction Centrifugal Pump

  1. Clean the grease and dirt on the base and place it on the foundation.
  2. Use a level to check the levelness of the base. Wedges can be used for leveling, and a level should be used for checking. The allowable levelness deviation is not more than 0.1mm/m.
  3. Pour cement into the base and anchor bolt holes.
  4. After the cement is dry, check whether the base and anchor bolt holes are loose. Tighten the anchor bolts after appropriate adjustments and recheck the levelness.
  5. Clean the supporting surfaces on the base, pump feet, and motor feet, and install the pump and motor on the base.
  6. The couplings should maintain a certain gap, and the centerline of the centrifugal pump shaft and the motor shaft should be checked for consistency. Thin shims can be used for adjustment to ensure concentricity.

Measure the upper and lower positions of the two couplings on the outer circle of the pump and the motor with a caliper. The measurement tolerance should not exceed 0.1mm. The maximum and minimum clearance differences between the end faces of the two couplings should not exceed 0.3mm in a week.

  1. Installation of flushing water pipeline for centrifugal pump. For the installation of the pipeline device for axial sealing (packing seal or mechanical seal) of the centrifugal pump, refer to Table 3.9-1 and Table 3.9-2.
  2. Installation of pressure gauge. If the pressure gauge is installed on the pump body of the centrifugal pump, first remove the threads on the inlet and outlet flanges of the pump body, install the pressure gauge joint on the threaded hole of the flange, and then install the pressure gauge on the joint. At this time, the valve on the joint should be closed.
  3. Installation of cooling water. For single-stage single-suction centrifugal pumps such as IR, IRG, and FN with cooling chambers, a cooling water system is required. During installation, first remove the two threads on the cooling chamber cover, connect the cooling water inlet and outlet pipes to the two threaded holes, and before starting the pump, turn on the cooling water system to fill the cooling chamber with water.

 

Installation Instructions for Single-stage Single-suction Centrifugal Pump

  1. The pipeline of the centrifugal pump should have its own support, and the weight of the pipeline should not be added to the pump to avoid damaging the pump.
  2. If a check valve is installed on the discharge pipeline, the check valve should be installed on the outside of the gate valve (away from the pump unit side).

 

Note: The translation may not be perfect and may require further editing for specific usage or context.

Related Pump Knowledge
More Pump Knowledge
13 Apr 2024
            Centrifugal pump and axial flow pump are two commonly used pump classes, they have a wide range of applications in industry. Although they...
Read more
07 Apr 2024
         The main function of the feed pump is to lift the deoxygenated water from the water tank or other water storage equipment and transport it in...
Read more
01 Apr 2024
          Recently, the design institute consulted to my company's industrial cooling water circulation system used in the co...
Read more
25 Mar 2024
Large displacement pump type           Large displacement pump, as the name suggests, is a pump with a very large flow, and ...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.