What you should know about the installation of denitrification chemical pumps

14 Sep 2021Email

As the largest source of nitrogen oxide emissions in my country's industrial sector, the coal and iron ore industries to achieve ultra-low denitrification emissions will be the key direction of atmospheric governance. The denitrification chemical pump is an indispensable equipment in the denitrification control system. If the denitration pump is installed incorrectly, the pump will not work properly, so let's take a look at what knowledge points should be known when installing the denitrification chemical pump.

Chemical pump

1. Basic selection

Before installing the denitrification chemical pump, the size, position, elevation and bolt hole position of the horizontal foundation should be rechecked to see if it meets the design requirements. The pump installation should be carried out after the concrete strength reaches the design requirements.

2. Pump body installation

1) When the anchor bolts are placed, the bottom end should not touch the bottom of the hole, the anchor bolt should be more than 15mm away from the edge of the hole, the bolt should be kept vertical, and the vertical deviation should not exceed 10/1000.


2) The leveling of the denitrification chemical pump should be based on the horizontal processing surface of the base, and measured with a level meter. The level deviation of the pump body should not exceed 0.1mm per meter. 3) Use a level, dial indicator or feeler gauge to measure and calibrate to keep the axis of the water pump and the axis of the motor coaxial. The axial inclination should not exceed 0.2mm per meter, and the radial displacement should not exceed 0.5mm. When you find that the pump is uneven when balancing, you can adjust the height with the horn.

3) The inlet and outlet of each pump of the denitration chemical pump should be equipped with drain and pressure gauge joints at both ends, and the inlet and outlet should be equipped with flanges for pipe connection.

Three, power connection

① The size of the power cord should meet the power requirements

② Leakage protection needs to be installed

③220V and 380V should pay attention to the positive and negative power lines to avoid reversal

④Water leakage protection


Four, debugging and running

The test operation of the denitration chemical pump should not be less than 2h continuously under the design load and meet the following requirements:

1. There should be no abnormal vibration and noise during operation, no leakage at each seal, and no loosening of fastening and joining parts;

2. The current and power of the motor should not exceed the rated value;

 

Five, denitrification chemical pump water pump maintenance

1: Install the bracket on the pipe near the pump so that there is no weight attached to the pump casing.

2: When the water pump is used up, the water in the water pump should be drained. It is best to remove the water pipe and rinse with clean water.

 

Six, matters needing attention

1: A shock-absorbing pad is installed at the bottom of the denitration pump, and the inlet and outlet pipes of the water pump are softly connected.

2: Pay attention to the waterproof of the electric control box

3: Filters must be added to the water inlet, and cut-off doors must be added before and after the pump

4: The inlet and outlet pipes should be sealed to avoid water leakage.

5: Protective measures should be taken when the pump is installed outdoors.

Related Pump Knowledge
More Pump Knowledge
13 Apr 2024
            Centrifugal pump and axial flow pump are two commonly used pump classes, they have a wide range of applications in industry. Although they...
Read more
07 Apr 2024
         The main function of the feed pump is to lift the deoxygenated water from the water tank or other water storage equipment and transport it in...
Read more
01 Apr 2024
          Recently, the design institute consulted to my company's industrial cooling water circulation system used in the co...
Read more
25 Mar 2024
Large displacement pump type           Large displacement pump, as the name suggests, is a pump with a very large flow, and ...
Read more
Related Products
More
Split Case Pump
Split Case Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Double Suction Pump
Double Suction Pump
  • Capacity:60-33005m³/h
  • Head:0.95-30.2bar
  • Price:$2200-215000
Single Stage Chemical Pump
Single Stage Chemical Pump
  • Capacity:5.5-2600m³/h
  • Head:1.6-25bar
  • Price:$4300-37000
End Suction Chemical Pump
End Suction Chemical Pump
  • Capacity:5.5~400m³/h
  • Head:0.42-12.5bar
  • Price:$560-9800
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.