What is the power consumption of the sewage pumping station?

17 Feb 2022Email

1. According to the water use plan of the service area (the amount of sewage water will not exceed the designed water amount for a long period of time), and the different water delivery volume of each pumping station, within the scope of the existing pumps, the pump of each pumping station entering the factory shall be monitored. make adjustments. The daily water delivery capacity of the pumping station is between 10,000 and 15,000 m3, so the four pumps with a power of 75 kW in the original design are changed to one with 55 kW and two 75 kW pumps; The daily water delivery volume is 3000-5000 m3, and the pump configuration is changed from the original 4 sets of 75 kW horizontal centrifugal pumps to 1 set of 22 kW and 1 set of 55 kW; the daily water delivery of the 7# vertical centrifugal pump station.The volume is 4000-5000 m3, and the configuration of the pumps is changed from the original three 75 kW pumps to one 22 kW and one 55 kW pump. Power consumption dropped by around 8%.

Sewage&Trash Pump

↑Click on the pic above to get 【sewage pump】 specs,price etc.↑


2. Transform the impeller of the sewage pump to improve the pumping efficiency

The original 75 kW and 55 kW pumps have lifts of 31 m and 41 m respectively, which are much higher than the actual lifting height (about 15 m) from the pumping station to the factory area, so the pump wastes a lot in terms of lift. That is to say, the design and selection of the original pump is quite different from the actual situation. Of course, replacing the pump is the easiest way, but a full pump replacement requires a lot of capital investment; it is also a good way to use the existing motor pump body to redesign and replace the impeller, but because the original pump is produced in Japan, plus the modification There are many types of pumps and few quantities, so far no manufacturers have been contacted that are willing to undertake this task (this work is still going on). For this reason, the water pump is transformed by means of cutting and adjusting the impeller. The so-called impeller cutting adjustment is to change the performance curve of the water pump by turning the impeller of the small water pump along the outer diameter to make it closer to the actual required lift and flow range, thereby improving the pumping efficiency of the water pump.

 

3. Pumping station automation transformation

The original chemical pumping station used simple relay-contactor control, which was completely controlled manually. In addition, the pump selection was too conservative. The capacity of a single pump was selected too large, and the lift selection was too high to achieve reasonable scheduling. , forming an impact load on the water quality and quantity of the plant area, and the power consumption is relatively large. For this reason, after the mechanical equipment of the pumping station is transformed, the automatic transformation is carried out. Each pumping station is equipped with a PLC and a frequency converter, and the water level value of the pumping room is detected by the water level measuring instrument, and the frequency of use of the pump and the number of openings are adjusted. , keep the pump running within the optimal efficiency range, reduce energy consumption, avoid damage to equipment caused by frequent startup, realize uniform water delivery to the plant area, ensure the economical and stable operation of the water treatment process in the plant area, and avoid sewage. Repeated flow in the pipe network. After this step of transformation is completed, the power consumption for water transmission is reduced by 29.5% on the basis of the previous transformation.

 

4. The sewage treatment plant has adopted a variety of transformation measures in view of the fact that the design of the centrifugal pump station is too advanced, the design quantity is too large, and the gap between the actual use and the pump station is too high. After all the renovations are completed, the actual water and electricity consumption of the entire pumping station is 43.9% lower than that before the renovation.

Related Pump Knowledge
More Pump Knowledge
27 Apr 2024
            When the O-ring of the multistage pump is damaged or aged, it needs to be replaced in time to ensure the nor...
Read more
20 Apr 2024
           Multistage centrifugal pump vs single-stage centrifugal pump: Which is more efficient? For this problem, the centrifugal pump professional ...
Read more
13 Apr 2024
            Centrifugal pump and axial flow pump are two commonly used pump classes, they have a wide range of applications in industry. Although they...
Read more
07 Apr 2024
         The main function of the feed pump is to lift the deoxygenated water from the water tank or other water storage equipment and transport it in...
Read more
Related Products
More
Need More Information?
Contact us for more details about our pump, solutions and services.
Contact ZB
Tel
0086 731 88192011
Leave a message
Name*
Tel
Email*
Area
Products
Split Case Pump
Metallurgy
Mining Industry
Urban Water Supply
Petrochemical
Light Industry
Electricity
Chemical Industry
Farmland Irrigation
Other
Provide your comments and questions.